Optimalisasi Ventilasi Ruang Kelas untuk Mencegah Penularan Covid-19 dengan Setting Experiment

Indonesia

Authors

  • Komarudin Komarudin Bina Nusantara University
  • Alfian Nasution Bina Nusantara University
  • Yohanes Baptista Indra Kurniadri Bina Nusantara University
  • Suharjito Suharjito Bina Nusantara University

DOI:

https://doi.org/10.37090/indstrk.v7i2.910

Abstract

The spread of the SARS-CoV-2 virus has forced many schools to implement health protocols such as wearing masks, social distancing, and limiting the number of students in classrooms when face-to-face learning resumes as it did before the pandemic. This is due to the World Health Organization (WHO) and the Centers for Disease Control and Prevention (CDC) stating that Covid-19 can spread through the air (airborne). In addition to implementing health protocols, another important thing is to maintain classroom ventilation. By increasing the ventilation of outside air into the classroom, the risk of virus transmission can be reduced, and the indoor air quality can be improved. Introducing as much outside air as possible into the room is one important way to prevent the spread of Covid-19 because it can reduce the concentration of the virus in the room. ASHRAE (American Society of Heating, Refrigerating, and Air Conditioning Engineers) recommends a minimum of 6 ACH (Air Change per Hour) for classrooms. Research conducted on one middle school classroom in Tangerang Selatan, equipped with 2 AC units and 1 window, showed that the ASHRAE standard can be met by opening the window at least 50% during learning activities and turning on 1 AC unit with the fan setting at full speed to achieve an ACH greater than 6. If besides wanting to prevent the transmission of Covid-19, you also want to create comfort during the learning process, you can turn on both AC units with the fan setting at low to full speed.

Keywords: Airborne, ASHRAE, Social distancing, US-CDC, WHO

References

Chen, C. Y., Chen, P. H., Chen, J. K., & Su, T. C. (2021). Recommendations for ventilation of indoor spaces to reduce COVID-19 transmission. Journal of the Formosan Medical Association, 120(12), 2055-2060.

Elsaid, A. M., & Ahmed, M. S. (2021). Indoor Air Quality Strategies for Air-Conditioning and Ventilation Systems with the Spread of the Global Coronavirus (COVID-19) Epidemic: Improvements and Recommendations. Environmental Research, 199, 111314.

Er Ding, D. Z.-S. (2023). Ventilation and thermal conditions in secondary schools in the Netherlands: Effects of COVID-19 pandemic control and prevention measures. Building and Environment, 229, 109922.

Fadli, d. R. (2023, February 1). Halodoc. Retrieved from Halodoc Web site: https://www.halodoc.com/kesehatan/coronavirus

Francesco Chirico, A. S. (2020). Can air-conditioning systems contribute to the spread of SARS/MERS/COVID-19 infection? Insights from a rapid review of the literature. International Journal of Environmental Research and Public Health, 17 (17), 6052.

Kafiuddin. (2020). Sistem Tata Udara Untuk Menekan Penyebaran Virus Covid-19. ASHRAE Indonesia Chapter, 13-14.

Prisca Winata, S. M. (2021, Juni). Kembali ke Sekolah dengan Aman dan Sehat di Masa Pandemi dan Pasca Pandemi COVID-19. Green Building Council Indonesia, I, 1-40.

Robertson, P. (2020, August 6). ASHRAE Recomended Air Changes per Hour. ASHRAE.

Sari, L. H. (2022, Maret). EVALUASI KUALITAS UDARA DAN KENYAMANAN TERMAL PADA RUANG KELAS PADA MASA PANDEMI COVID-19. ARSITEKNO, 9 (1), 21-30.

Sha, H., Zhang, X., & Qi, D. (2021). Optimal control of high-rise building mechanical ventilation system for achieving low risk of COVID-19 transmission and ventilative cooling. Sustainable cities and society, 74, 103256.

Tambani, L. S. (2020). High energy efficiency ventilation to limit COVID-19 contagion in school. Energy and Buildings, 240, 110882.

Thifal Indri Maulidina, A. B. (2020). OPTIMALISASI BUKAAN JENDELA KANTOR ASEAN SECRETARIAT DALAM UPAYA MEMINIMALISIR PENYEBARAN COVID-19. METRIK SERIAL TEKNOLOGI DAN SAINS (E) ISSN: 2774-2989, 1 (1), 1-7.

Yolanda, N., Putri, E. R., & Munir, R. (2022, December). Analisis Pertukaran Udara per Jam pada Ventilasi Laboratorium. Progressive Physics Journal, 187.

Downloads

Published

2023-07-10

How to Cite

Komarudin, K., Nasution, A., Baptista Indra Kurniadri, Y., & Suharjito, S. (2023). Optimalisasi Ventilasi Ruang Kelas untuk Mencegah Penularan Covid-19 dengan Setting Experiment: Indonesia. Industrika : Jurnal Ilmiah Teknik Industri, 7(2), 143–152. https://doi.org/10.37090/indstrk.v7i2.910